AmeriCool WMC-2500 Review: A 10,000 BTU Server Room Spot Cooler You Can Hang
AmeriCool's WMC-2500 is a 10,000 BTU, 0.8 ton spot cooler for server rooms that runs on 115V and can be used portable, rack mounted, hung or stacked.
The AmeriCool WMC-2500 Server Room Spot Cooler is a 10,000 BTU, 0.8 ton industrial spot cooler made for server rooms and data centers, with four installation options and a standard 115V supply. For more models, see our Portable Spot Coolers page.
Our Verdict
The WMC-2500 is the most flexible server room cooler we have looked at. It can roll on castors, sit in a rack, hang from the ceiling or stack, which makes it easy to fit into a crowded equipment room.
It costs more than other spot coolers of similar capacity, and AmeriCool does not list an efficiency rating or noise level.
AmeriCool WMC-2500 Server Room Spot Cooler
As an Amazon Associate we earn from qualifying purchases. Product prices and availability are accurate as of the date/time indicated.
Key Specifications
| Feature | Specification |
|---|---|
| Brand | AmeriCool |
| Model | WMC-2500 |
| Cooling | 10,000 BTU (0.8 ton) |
| Install | Portable, rack, hanging or stacked |
| Power | 115V, 15A, single phase |
| Refrigerant | R-410A |
| Controls | Remote |
| Size | 24 x 17.25 x 20 inches |
| Weight | 110 pounds |
Design
The ceiling mount is the standout option, because it frees the floor for racks and cable runs. On castors, it moves wherever cooling is needed during an outage.
It measures 24 by 17.25 by 20 inches and weighs 110 pounds, and it uses R-410A refrigerant.
Controls
A remote control handles operation, which is useful when the unit is hung high or tucked behind equipment.
It runs on 115V with a 15 amp, single phase supply, so it plugs into a standard outlet, and AmeriCool rates it for continuous operation.
Placement Tips
Put the cold air outlet within a few feet of the people or equipment you want to cool, and point the hot exhaust away from them. Indoors, run the exhaust to a drop ceiling, an open doorway or an exterior vent, otherwise the unit only moves heat around the room.
Leave open space around the intake so the unit can breathe, keep it on a level floor, and plug it straight into a grounded outlet on a circuit that is not shared with large tools. Outdoors, keep it out of standing water and under a roof or canopy unless the listing gives it a weather rating.
Running Costs and Care
Running cost depends on how many hours a day the compressor runs and on your electricity rate. Spot coolers draw far more power than a fan but far less than cooling a whole building, which is why they make sense for one work area or a short summer peak.
Clean or wash the air filter often, especially in dusty shops, and check the condenser coil for dirt and lint at the start of each season. Empty the condensate tank or check the drain line regularly, and before storing the unit, run it in fan mode to dry it out and drain all remaining water.
How It Compares
Against the Global Industrial water-cooled unit, the AmeriCool needs an exhaust path but no water lines, and it can be hung or racked.
Against the Tripp Lite SRCOOL24KE, the AmeriCool has less capacity but runs on a standard outlet instead of needing a 208/240V circuit.
Pros and Cons
| Pros | Cons |
|---|---|
| Four installation options | Premium price |
| Ceiling mount saves floor space | No efficiency rating listed |
| Standard 115V supply | No noise figure listed |
| Remote control | Needs exhaust ducting |
| Built for continuous use | Ceiling must carry 110 pounds |
Who Should Buy It
| Who Should Buy It? | Who Should Look Elsewhere? |
|---|---|
| Server closets | Large data centers |
| Small data rooms | Rooms with no exhaust path |
| IT spaces with little floor | Tight budgets |
| Offices with hot equipment | Outdoor use |
For more options, see our picks for the best spot coolers for server rooms and the best 110V spot coolers.
Final Verdict
The AmeriCool WMC-2500 Server Room Spot Cooler is a flexible server room spot cooler that can hang, rack, stack or roll and plugs into a standard 115V outlet. You can check the current price and details for the AmeriCool WMC-2500 Server Room Spot Cooler.
Frequently Asked Questions
How many BTU is the AmeriCool WMC-2500?
10,000 BTU, or 0.8 ton.
Can it be ceiling mounted?
Yes, along with portable, rack and stacked installation.
What power does it need?
115V, 15 amp, single phase.
Does it have a remote?
Yes.
How heavy is it?
110 pounds.